MWC UNIT # |
POLLUTANT OR PARAMETER |
START DATE |
TIME OF EXCESS EMISSIONS |
MONITORED LEVEL |
APPLICABLE LIMIT |
SPECIFIC REASON FOR EXCESS |
CORRECTIVE ACTIONS TAKEN |
2 |
CO |
9/30/2008 |
12:00 |
15:59 |
135 |
69 |
MALFUNCTION: FD fan fuses blew during startup. Emissions were above the limit for only 1-hour during the 4-hour compliance block. This is an excused excess emission event since the actual event was 3-hours or less in duration. |
Replaced fuses, tested and restarted motor. |
2 |
OPACITY |
9/30/2008 |
12:36 |
12:42 |
34.9 |
10 |
MALFUNCTION: Moisture carryover from FF compartments resulted in false-high reading. Note that reading are NOT indicative of particulate emissions. |
Ensure hopper heaters are operating correctly. |
2 |
OPACITY |
9/30/2008 |
12:42 |
12:48 |
17.7 |
10 |
MALFUNCTION: Moisture carryover from FF compartments resulted in false-high reading. Note that reading are NOT indicative of particulate emissions. |
Ensure hopper heaters are operating correctly. |
2 |
OPACITY |
9/30/2008 |
12:48 |
12:54 |
21.2 |
10 |
MALFUNCTION: Moisture carryover from FF compartments resulted in false-high reading. Note that reading are NOT indicative of particulate emissions. |
Ensure hopper heaters are operating correctly. |
2 |
OPACITY |
9/30/2008 |
12:54 |
13:00 |
19.1 |
10 |
MALFUNCTION: Moisture carryover from FF compartments resulted in false-high reading. Note that reading are NOT indicative of particulate emissions. |
Ensure hopper heaters are operating correctly. |