SEMI-ANNUAL REPORTING FOR CONTINUOUS MONITORING SYSTEMS AND STACK TESTING
MWC UNIT # POLLUTANT OR PARAMETER START DATE TIME OF EXCESS EMISSIONS MONITORED LEVEL APPLICABLE LIMIT SPECIFIC REASON FOR EXCESS CORRECTIVE ACTIONS TAKEN
2 CO 9/30/2008 12:00 15:59 135 69 MALFUNCTION: FD fan fuses blew during startup. Emissions were above the limit for only 1-hour during the 4-hour compliance block. This is an excused excess emission event since the actual event was 3-hours or less in duration. Replaced fuses, tested and restarted motor.
2 OPACITY 9/30/2008 12:36 12:42 34.9 10 MALFUNCTION: Moisture carryover from FF compartments resulted in false-high reading. Note that reading are NOT indicative of particulate emissions. Ensure hopper heaters are operating correctly.
2 OPACITY 9/30/2008 12:42 12:48 17.7 10 MALFUNCTION: Moisture carryover from FF compartments resulted in false-high reading. Note that reading are NOT indicative of particulate emissions. Ensure hopper heaters are operating correctly.
2 OPACITY 9/30/2008 12:48 12:54 21.2 10 MALFUNCTION: Moisture carryover from FF compartments resulted in false-high reading. Note that reading are NOT indicative of particulate emissions. Ensure hopper heaters are operating correctly.
2 OPACITY 9/30/2008 12:54 13:00 19.1 10 MALFUNCTION: Moisture carryover from FF compartments resulted in false-high reading. Note that reading are NOT indicative of particulate emissions. Ensure hopper heaters are operating correctly.