SEMI-ANNUAL REPORTING FOR CONTINUOUS MONITORING SYSTEMS AND STACK TESTING
MWC UNIT # POLLUTANT OR PARAMETER START DATE TIME OF EXCESS EMISSIONS MONITORED LEVEL APPLICABLE LIMIT SPECIFIC REASON FOR EXCESS CORRECTIVE ACTIONS TAKEN
1 CO 7/15/2005 400 759 906 69 economizer developed a tube leak and required shutdown using gas to minimize emisssions. 4 hour average based on 1 hour data repaired leak in tube
1 OPACITY 7/22/2005 0830 0836 12 10 when returning a fabric filter compartment to service it was found that the compartment had not been properly cleaned out Shutdown compartment and cleaned
1 NOx 10/6/2005 1600 1959 212 205 Startup, Daily average is based on 4 hours of operations with only 1 hour above emission limits adjusted SNCR equipment
2 CO 10/14/2005 1600 1959 379 69 When msw was admitted to grates gas burners tripped and had to be restarted.4 hour average based on 1 hour data Found Induced Draft fan linkage had malfunctioned and required linkage to be lubricated
2 CO 10/16/2005 2000 2359 92 69 Superheater Safety Valve lifted requiring steam flow load to be lowered to reseat the valve. 4 hour average based on 1 hour data. Used gas during event while pressure was reduced to allow safety valve to reseat. Contacted outside contractor of valve to come on site and repair.
1 CO 10/18/2005 0000 0359 2946 69 Induced Draft Fan Motor malfunctioned Unable to operate gas burners, safely secured unit and continued APC equipment to limit emissions
2 CO 10/18/2005 0400 0659 153 69 Startup following ID Fan malfunction Gas burners used to minimize emissions
2 CO 10/30/2005 1600 1959 72 69 Wet MSW caused plug in feed chute Manually stroked feeders to break up plug in feed chute, better mixing of wet msw
2 CO 11/10/2005 1600 1959 107 69 economizer developed a tube leak and required shutdown using gas to minimize emisssions. 4 hour average based on 1 hour data repaired leak in tube
2 CO 12/12/2005 2000 2359 113 69 Shutdown for planned maintenance activity Gas burners used to minimize emissions
2 CO 12/31/2005 0000 0359 99.1 69 Wet MSW caused plug in feed chute Manually stroked feeders to break up plug in feed chute, better mixing of wet msw