Emission/Parameter Data |
|
Duration of Event |
|
Unit |
Date |
Emission or Parameter |
Average Period |
Average Type |
Magnitude (ppm @ 7% O2) |
Emission Category |
From (hh:mm) |
To (hh:mm) |
Total Time (hh:mm) |
Reason |
Corrective Action |
1 |
9-Jul-01 |
CO |
04:00-08:00 |
4 hour block |
303 |
Shutdown |
04:53 |
05:39 |
0:46 |
shutdown for planned maintenance |
followed normal shutdown procedures |
1 |
12-Jul-01 |
CO |
12:00-16:00 |
4 hour block |
118 |
Start-up |
14:05 |
14:51 |
0:46 |
start-up after planned maintenance |
gas being burned only-- following normal startup steps to control emissions |
2 |
26-Aug-01 |
CO |
16:00-20:00 |
4 hour block |
205 |
Shutdown |
17:15 |
17:31 |
0:16 |
shutdown for tube repair |
gas burners kept tripping out, notified E/I personnel |
1 |
22-Oct-01 |
CO |
04:00-08:00 |
4 hour block |
152 |
Shutdown |
07:14 |
07:52 |
0:38 |
shutdown for planned maintenance |
followed normal shutdown procedures |
1 |
25-Oct-01 |
CO |
00:00-04:00 |
4 hour block |
85 |
Start-up |
00:14 |
00:23 |
0:09 |
start-up after planned maintenance |
gas being burned--MSW on grates |
2 |
5-Nov-01 |
CO |
16:00-20:00 |
4 hour block |
120 |
Shutdown |
17:33 |
17:57 |
0:24 |
shutdown for planned maintenance |
followed normal shutdown procedures |
2 |
6-Nov-01 |
CO |
16:00-20:00 |
4 hour block |
320 |
Start-up/ Malfunction |
17:43 |
19:05 |
1:22 |
start-up with gas/burners--burners tripped when fans started. Feeder malfunction when MSW went onto grates |
relit gas burners and repairs ensued to feeder malfunction |
2 |
25-Nov-01 |
CO |
12:00-16:00 |
4 hour block |
345 |
Shutdown |
12:29 |
12:43 |
0:14 |
shutdown for tube repair |
gas burners kept tripping out, notified E/I personnell |
2 |
26-Nov-01 |
CO |
08:00-12:00 |
4 hour block |
111 |
Start-up |
9:09 |
10:41 |
1:32 |
start-up after planned maintenance |
gas being burned only/repairs continuing on one gas burner |
2 |
26-Nov-01 |
CO |
12:00-16:00 |
4 hour block |
80 |
Start-up |
12:42 |
13:09 |
0:27 |
start-up after planned maintenance |
gas being burned--MSW on grates |
2 |
5-Dec-01 |
CO |
08:00-12:00 |
4 hour block |
392 |
Shutdown |
8:14 |
8:25 |
0:11 |
shutdown for tube repair |
gas burned using one burner/ E/I notified on malfunction |
1 |
19-Dec-01 |
Carbon Feed |
00:00-08:00 |
8 hour block |
11PPH |
Malfunction |
07:08 |
08:06 |
0:58 |
carbon screw feeder alarm showed feeder running,but was not which caused 1 hour low feed rate during 8 hour period |
requested engineering firm to program different alarm set-up,increased feed rate but could not achieve desired results for 8-hour period |