Plant Name: Wheelabrator North Andover, Inc.
Subpart FFF/Cb Annual Report, 40 CFR 39b (a) /40 CFR 60.59b (g)
Reporting Period: From: 17-Feb-01
  To: 31-Dec-01
 
1. Section 40 CFR 59b(g)(1)(i) - 2 Year Annual PerformanceTest Results
 
  Current Year Previous Year Current Year Previous Year
  Unit 1 Unit 1 Unit 2 Unit 2
Emission Test Result Test Result Test Result Test Result
Particulate Matter, mg/dscm @ 7% O2 1.4 N/A 1.0 N/A
Opacity, % 0 N/A 0 N/A
Cadmium, mg/dscm @ 7% O2 0.00065 N/A 0.00035 N/A
Lead, mg/dscm @ 7% O2 0.0207 N/A 0.0138 N/A
Mercury, mg/dscm @ 7% O2 0.0202 N/A 0.0133 N/A
Mercury Removal % 87 N/A 94 N/A
Dioxins/Furans, ng/dscm @ 7% O2 0.6 N/A 0.8 N/A
Hydrogen Chloride, ppmdv @ 7% O2 7.7 N/A 8.0 N/A
Hydrogen Chloride, % Removal 99 N/A 99 N/A
 
Fugitive Ash, % Current Year 0 Previous Year N/A
 
2. Section 40 CFR 60.59b(g)(1)(ii) - Highest Recorded Emission Levels From CEM Data
 
  Current Year Previous Year Current Year Previous Year
Emission or Parameter Unit 1 Unit 1 Unit 2 Unit 2
Sulfur Dioxide, ppmdv @ 7% O2
(24-hour geometric average)
25.5 N/A 26.4 N/A
Nitrogen Oxides, ppmdv @ 7% O2
(24-hour arithmetic average)
204 N/A 210 N/A
Carbon Monoxide, ppmdv @ 7% O2
(4-hour block average)
469 N/A 392 N/A
Unit Load, lbs/hr steam
(4-hour block average)
170 N/A 171 N/A
Fabric Filter Inlet Temperature, deg F
(4-hour block average)
331 N/A 329 N/A
 


Plant Name: Wheelabrator North Andover, Inc.
Subpart FFF/Cb Annual Report, 40 CFR 39b (a) /40 CFR 60.59b (g)
Reporting Period: From: 17-Feb-01
  To: 31-Dec-01
 
3. Section 40 CFR 60.59b(g)(1)(iii) - Highest Measured Opacity Level
 
  Current Year Previous Year Current Year Previous Year
Emission Test Result Test Result Test Result Test Result
Opacity, %
(6-minute block average)
3.5 N/A 9.0 N/A
 
4. Section 40 CFR 60.59b(g)(1)(iv) -Total Days CEMS Did Not Obtain Valid Data for 75% of Boiler Operating Time
 
  Current Year Previous Year Current Year Previous Year
Continuous Emission Monitor Unit 1 Unit 1 Unit 2 Unit 2
Sulfur Dioxide, ppmdv @ 7% O2 6 N/A 3 N/A
Nitrogen Oxides, ppmdv @ 7% O2 5 N/A 3 N/A
Carbon Monoxide, ppmdv @ 7% O2 3 N/A 1 N/A
Unit Load, lbs/hr steam 0 N/A 0 N/A
Fabric Filter Inlet Temperature, deg F 0 N/A 0 N/A
 
5. Section 40 CFR 60.59b(g)(1)(v) - Total Number of Hours CEMS Data Was Excluded From Calculations
 
  Current Year Previous Year Current Year Previous Year
Emission or Parameter Unit 1 Unit 1 Unit 2 Unit 2
Sulfur Dioxide, ppmdv @ 7% O2 105 N/A 68 N/A
Nitrogen Oxides, ppmdv @ 7% O2 80 N/A 65 N/A
Carbon Monoxide, ppmdv @ 7% O2 55 N/A 40 N/A
Unit Load, lbs/hr steam 0 N/A 0 N/A
Fabric Filter Inlet Temperature, deg F 0 N/A 0 N/A


Plant Name: Wheelabrator North Andover, Inc.
Subpart FFF/Cb Annual Report, 40 CFR 39b (a) /40 CFR 60.59b (g)
Reporting Period: From: 17-Feb-01
  To: 31-Dec-01
 
6. Section 40 CFR 60.59b(g)(3) - Highlight of Emission or Parameter That Did Not Achieve Emission Limit
 
Emission or Parameter Unit # Date Magnitude Explanation Summary
Carbon Monoxide 1 4/8/01 469 shutdown - planned maintenance
Nitrogen Oxides 2 4/16/01 210 malfunction - urea pumps tripped
Carbon Monoxide 2 12/5/01 392 shutdown - tube repair
Wheelabrator North Andover
285 Holt Rd.
North Andover, Massachusetts, U.S. 01845
Tel: 978.688.9011

Copyright © Wheelabrator North Andover